You are currently browsing the archives for the Life Safety Hardware category


Ligature Resistant Door Hardware

Left: Marks USA Lifesaver series. Right: TownSteel MRXA series.

Ligature resistant, otherwise known as anti-ligature or behavioral health door hardware is designed to make it difficult for folks to use it for suicide by hanging or otherwise harming themselves or others.  Pictured adjacent are cylindrical knob and lever locks by Marks USA and a mortise lock by TownSteel.

All are designed to resist attempts to hang oneself.  The cylindrical lever and knob locks feature more or less conical designs that cause a cord to slide off of them regardless of how one might try to tie it on.  The lever turns freely even when locked, achieving the same result.  The mortise lock uses a conical cylinder collar and sloped trim to achieve ligature resistance.  The opening in the pull is closed by a steel plate, making it impossible to pass a cord through it.  The exposed fasteners are security fasteners that require a special tool to loosen, and they fit flat and flush to the escutcheon and lock front.

When you sell or install ligature resistant hardware it is best not to modify the product in any way, because in doing so you will assume all responsibility for anything that happens as a result involving the hardware.  This can include disassembling a cylindrical lock to rekey it.  For this reason I recommend that when keyed anti-ligature locks are specified they are specified as interchangeable or removable core locks.

Ligature resistant hinges have hinge tips called “hospital tips” that are sloped to discourage suicide attempts (see McKinney hinge adjacent).  Security screws also help keep folks safe by making it difficult to use the hinge to hurt oneself or others.   Select Hinge offers a little gem called the “Tipit” for continuous hinges that makes continuous hinges ligature resistant.

Increasingly I field inquiries for ligature resistant door closers for butt or offset hung doors, but to my knowledge there is no such animal as of this writing.  Various factory tech support people have recommended overhead concealed security closers for ligature resistant applications, and this seems to be the consensus at this time.

I believe that using doors that are center hung with single acting, concealed overhead or floor closers would be safer and would eliminate the need for anti-ligature hinges; but this is impractical for retrofit applications where butt or offset hung doors are already present in abundance.

In the illustration below I show why I feel a center hung, concealed, single acting door closer would be the best choice for ligature resistance.





In door hardware, safety is the most important consideration.

 

locksnsafescom

Your source for quality security products with superior service!

The Time-Out Room

DormaKaba Stanley Best SSRL seclusion room lock.

The “Time-out Room,” also called a “Seclusion Room,” is, perhaps, a sign of our times. The purpose of a time-out room in a middle school or elementary school is to temporarily segregate an out-of-control student from the rest of the school population.  As you can imagine, the use of a seclusion room is heavily regulated, and regulations vary from state to state, city to city, and even institution to institution.  However, there are some common rules.  For example, such rooms are required to be equipped with a means to see and communicate with the student while they inside the room; the room must be free of objects and conditions that might be potentially dangerous; and the door must be unlocked from the inside.  The room must also be large enough for the student to lie down in without touching a wall, and must have a high enough ceiling that the student will not have to bend.

The purpose of the room is to let the student cool off and calm down before rejoining the school population.  It is not a holding cell.  Its purpose is less as a punishment than a behavioral tool.

What stops the student from leaving the seclusion room?  A person keeps them in.  A person must be present to observe and make sure the student is safe.  I venture to say that same person is the one who gets the student into the room in first place and keeps them there.  With no great stretch of the imagination, one might foresee instances in which the student to be secluded might be significantly bigger and stronger than the person responsible for keeping him and others safe.  It might be physically impossible for the responsible person to keep the student in the room.  They might need help.

The answer could be to put someone large, strong and well-versed in non-lethal martial arts with the patience of a saint in charge of the seclusion room duties, or it could be to use some kind of locking device to keep them in.  But, wait!  You can’t lock them in.  It’s against the rules.  How do you solve the problem?

Often the answer is an electromagnetic lock controlled by a normally open, momentary contact switch.  The magnet is only activated when the button is pressed.  As soon as the responsible person takes their hand off the button the mag lock is unlocked.  Often, local or institutional rules governing seclusion rooms require a time limit on seclusion.  One could add a timer to the system that would automatically release the electromagnetic lock after the permissible amount of time has expired.  Life safety code would demand that the magnetic lock be disabled by the fire alarm.

Pictured above is the Stanley Best SSRL seclusion room lock as seen under the Behavioral Health Products section at the bestaccess.com web site.  One must stand there and hold the lever in position to temporarily secure the door.  In photo we can see that the door is a hollow metal door in a hollow metal frame, and the door has a lite kit in it with wire glass.  I’ll bet it’s a heavy gauge, reinforced steel door, too, judging from the three-point locking version of the SSRL shown.  Clearly they expect trouble.  Through the window they can observe the student and make sure that they are safe.

Since we can see the knuckles of the hinges we know the door swings out.  This eliminates the need for a ligature-resistant handle on the inside of the door.   We’ll talk more about ligature-resistant hardware soon.





Sometimes you just need a little time.

 

locksnsafescom

Your source for quality security products with superior service!

Card In / Card Out Access Control

“Card-in / Card-out” refers to an access control system that is also an egress control system.  Users are required to present their credential both when they enter and when they exit.  Requiring employees to card in and out can simplify time and attendance tracking,  Requiring a credential to exit a secured space can reduce the risk of theft and help prevent unauthorized visitors from entering and exiting restricted areas.

When card-in/card-out systems are used to track employee hours, employees must present their credential to gain entry to their workplace and again when exiting to record their hours at work.  In this case there is no impediment to egress and life safety code is not affected.  When the purpose of the system is to only allow egress with presentation of a valid credential, this is where complication often sets in.

Frequently life safety codes and building security are seemingly at odds in their hardware requirements, and card-in/card-out systems can be one of those situations due to the ‘card-out’ side of the equation.  Life safety code demands that door hardware provide free egress with one motion with no prior knowledge required.  Therefore, a card-in / card-out system is potentially two violations in one, requiring prior knowledge (knowing that you need to bring your credential) and two motions (1. Present your credential, and 2. Push the door open); so it is a good idea to consult with your local Authority Having Jurisdiction (AHJ) before installing a card-in / card-out system that impedes free egress by demanding a credential.

The components necessary to create a card-in / card-out system are:

  1. Access Control Panel
  2. Exterior credential reader
  3. Interior credential reader

If the system will allow free egress this is all you need.  Most existing access control systems can be configured to accommodate card-in / card-out operation.  If the object is to record employee time and attendance, check with your access control company to see how their software can provide your Human Resources department or payroll service with attendance data.

If the system must restrict egress, one way to do so is to program the system to sound an alarm when a user attempts to exit without presenting their credential.  The alarm provides a deterrent to motivate compliance, and the alarm event can be time-stamped in the access control audit trail record.  If video surveillance is in service at the opening, the access control system can signal the CCTV system and images of the non-compliance event can be captured.  The alarm could be programmed to reset automatically when the door closes, or only when a valid credential is presented.  There are many options.

To further restrict egress, a delayed egress system can be added.   Delayed egress systems are highly regulated by fire safety code, so all delayed egress systems behave in similar ways:  after pressure is applied to the door or device for two or three seconds, an alarm sounds for fifteen seconds and then the system allows the user to exit.  The alarm continues to sound until the system is reset.  To comply with fire safety code the system will have signage on the door:

Von Duprin Chexit door label from Chexit installation instructions.

There are some variations.  For example, instead of two or three seconds of pressure on the door, some jurisdictions allow the fifteen-second alarmed delay to begin sounding right away; with written permission from the local Authority Having Jurisdiction (AHJ) it is possible to have a thirty-second alarmed delay instead of fifteen seconds; some jurisdictions will allow the delayed egress system to self reset, others demand that the system be reset at the door.  Consult with your local AHJ for details.

The effectiveness of delayed egress as a prevention of unauthorized egress is dependent upon how fast personnel can respond, especially if the intent of the system is to inhibit theft.  I imagine that fifteen seconds seems like a very long time to someone who has just set off the alarm and is waiting to escape with their stolen industrial secrets or whatever, but it is really not a long period of time in which to apprehend a thief.  On the other hand, if the thief had to pass a security guard after getting past the delayed egress system, s/he would be less likely to escape.





Life safety is never to be ignored.

 

locksnsafescom

Your source for quality security products with superior service!

Exit Device Retrofitting Adventures

Monarch model 18

As door hardware evolves, new products emerge to replace older products. This may happen because of a design improvement, or because a company changes ownership, but in either case it means that there are older products in the field for which there are no exact replacements. Any door hardware product may become obsolete over time. Today we are talking about exit devices.

Falcon Model 25

In the mid-Twentieth Century mass production of doors was standardized so that the mortise pocket within a door that houses the mortise lock would always be the same size. Before this standardization mortise locks were available in a wide variety of sizes, but from this time forward all architectural grade lock fronts would be eight inches tall by one-and-a-quarter inches wide. Of course this affected mortise exit devices. So when I went to replace a Von Duprin 8875 mortise exit device manufactured sometime between 1897 and 1920, I found that the mortise pocket was only about six inches tall and I had a bit of cutting to do to make the new device fit.

Companies pay varying attention to the ‘retrofit-ability’ of their products. Some companies make it easy to replace an old device with a new one, and some do not. As an installer it is easy to find oneself marooned out in the field, having identified an exit device by its appearance for the purpose of providing an estimate to replace it, only to find out during installation that it is the old version, and installing the new version is either going to be a lot of extra work, or extra hardware that was not on the estimate.

For example, in the late 1990’s Von Duprin redesigned their narrow stile 33 and 35 series exit devices. The rails remained the same, but the heads were completely changed. The old version did not accept a rim cylinder tail piece, and the new one does. This means the old outside trim will by no means work with the new device – a potentially expensive problem if not anticipated.

Similarly the Precision 2000 series Apex devices are not backwards compatible with the old 1000 series trims.

Monarch was bought by Ingersoll Rand and rebranded under the Falcon line of products, now part of Allegion. During these transitions the trims changed part numbers two or maybe three times. Check with your favorite hardware genius as to whether the trim you have will work with the device you need.

The lesson here is not to judge by appearances. The new Von Duprin 33 looks a lot like the old one and the Precision 2000 looks just like the 1000 series. To avoid expensive mistakes, pull the device off the door and positively identify it before you write your estimate.

Both Doromatic and Jackson responded to the need to replace crossbar devices with touch bar devices by creating touch bar versions that fit the same footprint as their crossbar predecessors. The Doromatic 1690 and 1790 devices replace the 1990 and 2090, and the Jackson 2085 and 2095 replace the 1085 and 1095 devices with very little trouble. A big bonus is that a in the case of the 2085 Jackson and the 1690 Doromatic concealed vertical rod devices, you can reuse the exiting concealed vertical rods.





Knowing what you have is the key to knowing what you want.

 

locksnsafescom

Your source for quality security products with superior service!

Field Reversing the Precision E2203 SVR Exit Device

The Precision E2203 is a Surface Vertical Rod exit device with a solenoid in the head that controls the outside lever trim.  Ordered complete with trim: part number is E2203 × 4908A, specify door width, finish, handing, fail safe or fail secure.  The right thing to do is to order it fail safe or fail secure and handed at the factory for your application. 

But… let’s say for the sake of this article that you ordered the device and did not specify handing or fail safe / fail secure. You might find yourself needing to field reverse the handing.  Here is what you need to know.

Handing

Changing the hand on the basic 2200 device is not very difficult, but changing the hand on the E2200 is fairly difficult, and requires skill, patience and … tape.
For the non-electric, purely mechanical version of this device, changing the hand is not as simple as it is with some other exit devices, for example, flipping the device over, but it is not all that hard to do.  Below are the directions for field handing excerpted from the 2200 Series installation instructions from the Stanley Precision web site.   Why they have arranged the steps to be followed in counterclockwise order is a mystery to me, but I am not here to judge, just inform.

At a glance you can see that there is some disassembly of the exit device head required to change the handing of the device. But when you add electrified trim control it complicates things a bit.

In the photo below you see the wires for the solenoid where they pass through the hole in the bracket.  That bracket is an integral part of the active head and it does not move.  However, the solenoid must be installed at the other end of the active head in order to interface with the working parts of the device and the wires are just long enough to allow it to be installed where it is.  There is no play in the wire that would allow the wire to remain where it is and yet allow one to move the solenoid.

 

 

 

In order to move the solenoid to the other side of the active head, one must either cut the wires (a nightmare, do not do it) or to completely disassemble the exit device, bar and all.

Why do you have to completely disassemble the exit device to pull the wire through?  Because it is taped to the baseplate of with a piece of filament tape that runs the length of the bar.  The tape must be removed to free the wire so you can pull it out through the hole in the bracket.

I could not find the directions for changing the hand of the E2203, but here is a drawing of the solenoid placement for the E2103 rim exit device taken from the installation instructions from the E2103 Kit.

 

 

Once you have pulled the wire through the hole, changed the hand of the head, taped the wire back down the length of the bar baseplate and reassembled the device, you’re done.

Below is a picture of the E2203 with handing freshly changed and the device reassembled and ready to install.

 





Like I said: order it fail safe or fail secure… AND ORDER IT HANDED.

 

locksnsafescom

Your source for quality security products with superior service!

Experiencing the New Von Duprin Chexit

Chexit door label from Chexit installation instructions.

Von Duprin Chexit door label from Chexit installation instructions.

Last year Von Duprin began shipping Chexit self-contained delayed egress exit devices that are motorized instead of solenoid driven.  Since they are motorized, the new Chexits draw less current and will probably be more reliable than the previous solenoid-driven version. This means a less serious, less expensive power supply, less need for high capacity, high gauge, high cost wire and greatly increased workable wire run distances – all good things.

The new Chexit will do everything the old Chexit did, including release of the outside lever trim when the external inhibit function is activated by access control or another external switch.  That remains a way to get access control out of a Chexit by simply adding a blank escutcheon or other unlocked outside trim to the Chexit exit device.

As of this writing Exit-only function Chexit devices were being shipped less the part number 040193-00 cable used to connect the E996L to the Chexit PC board.  The cables are only provided if you order the Chexit from the factory with trim, but that is okay as long as you want to use no trim or non-electric trim.  Electrified trim is a means to provide fail secure access control from the trim side, so if the fire alarm goes off and powers down the Chexit, the fail secure electrified trim will stay locked.  Entry can still be gained by key.

On another note, recently I was involved in an application where the installer was replacing a mortise exit device and wanted delayed egress from the push side and free ingress from the pull side.  Luckily it was a mortise device, so all I had to do was provide a Chexit mortise exit device with blank escutcheon (passage function) trim because THE MORTISE LOCK ACTS INDEPENDENTLY FROM THE CHEXIT ON THE TRIM SIDE. Cool. 🙂

Bear in mind that  the Chexit remains active while people are using the passage function trim to get in, so if they happen to depress the touch bar, say by bumping it up against the wall for two seconds, they may activate the Chexit alarm.   Von Duprin Tech Support suggested a palm switch on the trim side to activate the inhibit circuit in the Chexit while a person enters from that side.

 





It was fun, easy, and I looked like a … Hardware Genius.

Choosing a Delayed Egress System: Self-Contained, or Built from Components?

Delayed egress is a process that delays unauthorized exit from a space while complying with NFPA 101 life safety code.  Use of this process is strictly regulated with the help of building inspectors and fire marshals across the United Sates.  With that in mind it is always a good idea to get your local AHJ (Authority Having Jurisdiction) on board whenever you are planning to install delayed egress on an opening.

When you beginning planning your delayed egress system you will find that many systems on the market are self-contained.    These could be delayed egress electromagnetic locks or electrified delayed egress exit devices.

Here are some examples of self-contained delayed egress maglocks:

  • SDC 1511S
  • Schlage Electronics M490DE
  • Dynalock 3101C

Here are some examples of self-contained delayed egress exit devices:

  • Detex V40 EE
  • Von Duprin Chexit
  • Sargent Electroguard

delayed-egress-anatomy
Almost all delayed egress systems are made up of the same components:

  1. Delayed egress timer and relay logic board
  2. Initiating Switch (to initiate the delayed egress process)
  3. Audible alarm
  4. Signage
  5. Reset switch
  6. Optional bypass switch
  7. Fire Alarm interface
  8. Power supply
  9. Locking device

Therefore it is possible to construct a custom delayed egress system from components.  Later I’ll talk about why you might want to choose a built-from-components delayed egress system instead of a self-contained one.   The following sections describe each part of a built-from-components delayed egress system.

Delayed Egress Timer and Relay Logic Board

This board is UL Listed and specifically designed to perform all delayed egress functions in compliance with life safety code.   Here are some examples of component boards for delayed egress:

  • Securitron XDT-12 or XDT-24
  • Seco-Larm SA-025EQ

The board is the brains of the delayed egress operation.  It has contacts to wire in switches for delayed egress initiation, fire alarm interface and system reset, timers to control nuisance and egress delay, and relays to control locks and notify external devices.

There are also delayed egress controllers that offer more features.  The following may include the delayed egress timer/relay board and some other required feature(s) such as the initiation switch or the audible alarm.

  • Alarm Controls DE-1
  • Security Door Controls 101-DE
  • Securitron BA-XDT-12 or BA-XDT-24

Initiating Switch

The switch that initiates the delayed egress process shares several characteristics with any request-to-exit switch.  To comply with life safety regulations it must require no prior knowledge to operate; it must require no more than one motion to operate; and it must be placed in relation to the door according to life safety standards in your local jurisdiction.  I think that the best possible initiation device is a mechanical push bar with a switch, such as the Adams Rite 8099-M or the Securitron EMB.  In a panic situation it remains obvious that to get out, one must push on the bar, and because it is mechanical it is unaffected by power outage.  If it is wired to open the contact when pushed, if the wires leading to it are cut it will initiate the delayed egress process.

In rare circumstances where it might be permitted, the locking device might be a fail safe electrified mortise lock that is locked on both sides, inside and out.  Then the initiation switch might be a palm switch next to the door.

Audible Alarm

The mandatory audible alarm sounds for 15 seconds before the delayed egress controller releases the locking device to allow exit.  It’s loudness must be between 81 and 88 decibels.  In some jurisdictions the alarm must be manually reset at the door; in others it may be self resetting via timer or door position switch.  Yet another reason to have a heart-to-heart talk with your local AHJ when designing your delayed egress system.

Signage

The wording on the mandatory sign must comply with life safety code.  There are minor variations in wording.  I suggest buying a sign that is part of a delayed egress system.  The sign that comes standard with the Von Duprin Chexit is readily available as a separate part.

Reset Switch

As mentioned in the “Audible Alarm” section above, a delayed egress system reset switch located at the door is mandatory in some jurisdictions.  Check with your local AHJ.  In some jurisdictions delayed egress systems are allowed to be reset by remote switch or other means, such as a door position switch.

Any kind of momentary contact switch will do the reset switch job, but delayed egress system reset switches located at the door almost always require some kind of security to prevent unauthorized resetting.   Standalone keypads or key switches are often used for this purpose.  Delayed egress systems can also be integrated into existing access control.

Optional Bypass Switch

Not required but often needed, the optional bypass switch allows authorized personnel to exit without triggering the delayed egress system.  Again, any momentary contact switch will do, but usually some security is required.  If you are using a keypad as the system reset switch and the keypad has more than one relay, you can program the second relay to be the bypass switch.

If access from the exterior side is required a bypass switch is required on that side.  Sometimes security is not needed from the exterior side.  In that case a simple momentary contact pushbutton will do the job.

Fire Alarm Interface

The mandatory fire alarm interface allows enables fire alarm panel to deactivate the delayed egress system immediately in the event of a fire alarm.  This is an integral part of the life safety code that allows a delayed egress system to exist.  Therefore, if your building does not have a fire alarm panel, without special permission from the local AHJ you cannot have a delayed egress system.

Power Supply

All delayed egress systems I have had experience with run on low voltage power that comes from a low voltage power supply.  Generally delayed egress systems require regulated and filtered power at 12 or 24 volts.  Delayed egress controllers draw very little current, but as will all electrically operated systems, the current draw of all attached devices must be taken into account when selecting a power supply.

Locking Device

The locking device must be electrically locked and fail safe from the egress (interior) side.  The most frequently used locking device in a component based delayed egress system is the electromagnetic lock.

Why Build a Delayed Egress System?

Why would you put together a delayed egress system from components when there are so many good self-contained systems?

  1.  To Save Money.  Piecing together a delayed egress system can be significantly cheaper than buying a self contained delayed egress system.
  2.  To take advantage of existing hardware.  For example, if there is already an electromagnetic lock on the door, adding the other components is relatively easy.
  3. Conditions at the door prohibit use of a self contained delayed egress system.  For example, door size or the presence of existing hardware may require the installer to seek a more creative solution.

 





Bottom line, unless you have a prison, you cannot lock ’em in.  Well, not without permission.  🙂

How to Order Door Hardware for Small Commercial Projects

This article is for facilities or property managers who need to buy hardware for change-of-use projects in which there is no architect involved.

On larger projects that involve build-outs or new construction, along with the doors architects usually specify the door hardware, often with the help of an Authorized Hardware Consultant (AHC).  On smaller projects wherein the services of an architect are otherwise not required, hardware choices often fall to you:  the facilities or property manager or owner.  This article will provide language and concepts that will facilitate communication between you and your hardware dealer and/or installer.

Get Good Advice

If you do not already have one whom you do business with, choose a qualified hardware installer.  I may be a little biased, but I think locksmiths make the best hardware installers.  Some contractors also have hardware installation specialists on staff who are qualified to do the work.  Experienced and qualified hardware installers can help answer your questions as you tackle this project.

Specifying the wrong hardware can be expensive, so your hardware choices can be very important.  In addition to your hardware dealer or qualified installer, your local building inspector and fire marshal can be invaluable sources of information.  They will be able to tell you, for example, if a particular door needs panic hardware and/or fire rated hardware.  Your qualified installer should also be able to help with these choices, but if there is ever a choice you are not sure of you can always consult these governmental authorities.

 

Know Your Doors

Number Your Doors 

Assign each door a number.   Stick a label with the door number on every door on the edge on the hinge side, just above the top hinge.   List the door numbers across the top of a spreadsheet.   Under each door number enter the existing hardware, door dimensions and other characteristics as discussed in the following sections.

Existing Hardware

Do a survey of the property and catalog every door, hinge, kick plate, door closer and lock.  Base your notes on the following categories of information in this article and you should be able to answer most questions your hardware installer may have without them having to visit.  You get two benefits from this:

  • Knowledge of what you have and what you want
  • Savings of time and therefore, money

List every hardware item on every door.  Be sure to open the door and look on both the inside and the outside.  Below is an illustration of some of the different kinds of hardware one may find on a door.

hardwaredoors

Don’t forget the wall or floor stops.

You may ultimately decide to reuse your existing hardware if it suits your intended use of the space and is in good working order.  You may need to rely on your hardware installer to help you determine what may be kept and what should be discarded.

Fire Rated vs. Non Fire Rated

Fire rated doors are designed to resist the spread of a fire within a structure.  Fire rated doors get their fire rating from Underwriters Laboratories and have a UL label on them showing the fire rating.  Only fire rated hardware can be used on fire rated doors if the fire rating is to be maintained and your project is to pass inspection.  Interior stairwell doors are always fire rated.  Other interior doors often may be fire rated as well.  Check all doors for fire labels; consult your local Fire Marshal if you are unsure.

thicknessLocks for fire doors are UL listed as such and must positively latch whenever the door is closed.  Without exception, fire rated doors must be closed and positively latched in the event of a fire.   Therefore fire rated doors always have a door closer and some kind of UL listed latching device, such as a mortise lock, fire rated exit device or UL listed cylindrical lock.

Non-fire rated exit devices may have a “dogging” mechanism that keeps the push bar pushed in so that the latch(es) remain retracted.  Usually this is apparent as a small hole in the bar where a hex key can be inserted to dog the device down.  Sometimes the dogging mechanism is operated by a key cylinder.  If your device is equipped with any kind of dogging it is not a fire rated device.

Fire rated doors must be equipped to self-close.  This must almost always be accomplished through the use of a door closer.
Exterior doors are not usually fire rated, or if they are labelled may not have to comply with the positive latching rule.   Consult your local fire marshal or building inspector if you have any question.

Failure to comply with fire and life safety code can have expensive consequences so use extra care.

doordimensionsDimensions

Accurate dimensions of door and frame are vital when choosing door hardware.  Here are some common door measurements:

  • Width
  • Height
  • Thickness
  • Reveal
  • Stile width
  • Rail height

Door Width and height can be important when you are choosing a door closer or an exit device, and vital in complying with the American Disability Act (ADA) that requires openings to provide 32 inches of passage clearance.   This includes the space occupied by the open door.

reveal

The Reveal.

Door thickness can be important when ordering door closers, exit devices and locks.  Reveal dimension is important for certain types of door closer installations.

As shown in the illustration below, the stile is the vertical part of a door that is made up of the components, stile and rail, whereas the rail is the horizontal part.  Most stile and rail type commercial doors are aluminum, although more and more of them are Fiber Reinforced Plastic.

 

alumstileandrail

Stile width is important when ordering locks or exit devices.  Rail height is important when ordering door closers or electromagnetic locks.

Photos of doors are also good to have, but are not a substitute for accurate measurements.  

Handing

The “hand” of a door describes the direction it swings in relation to its hinges.  If you imagine yourself being the hinge, and your right hand is on the door while your left hand is on the frame (like the person in the picture), the door is Right Hand.

handingwithhands

His right hand shows that this is a right hand door.

 

T-handing

Doors are always Left Hand (LH) or Right Hand (RH) however some locks can be Left Hand, Right Hand, Left Hand Reverse (LHR) or Right Hand Reverse RHR).   “Reverse” means that the locked side of the door is the pull side.  If a ‘reverse’ handed lock is installed on a Right Hand door, the lock is said to be Left Hand Reverse.  If it is installed on a Left Hand door it is said to be Right Hand Reverse.

All exit devices are reverse handed.

Location

The location of a door affects the hardware that can be installed on it.  For example, locking exterior doors in commercial facilities designed to accommodate a given number of people are usually required to have panic hardware – that is, an exit device with a push bar that goes across the door, the actuating portion of which must measure at least half the width of the door.   Most exit devices easily comply with this requirement.

All life safety code compliant buildings have a “path of egress,” that is, a clearly marked escape route in case people need to get out of the building in a hurry if, for example, the building is on fire.   Electrically lit exit signs are usually required to be placed along the path of egress to show people where they need to go.  Doors located in the path of egress are referred to as “egress doors” and are almost always required to swing in the same direction as the path of egress.

As previously discussed, while exterior doors are rarely fire rated, interior doors are often fire rated.  Fire rated doors need to be positively latched in the event of a fire, so if you are using exit devices with electric latch retraction, the latches must be extended in the event of a fire; if you are using fire rated electric strikes, they must be locked in the event of a fire.  Usually this is achieved (in both cases) through the use of a fire alarm interface relay, which is a device by which the fire alarm system can interrupt power to locking devices in the event of a fire.

Stairwell doors are unique in that not only are they fire rated – so they must be positively latched in the event of a fire – they must also usually be unlocked in the event of a fire.  This is all fine and good if locking the stairwell doors is not required, (passage function mortise or Grade 1 cylindrical locks or fire rated exit devices with passage function trim will all do the job just fine) but when access control is required the range of choices is limited.  Electric strikes cannot be used, but electrified fail safe mortise or cylindrical locks can be used as well as electrified fail safe exit device trim.  All such devices must be automatically unlocked by the fire alarm system as described above.

Composition

What is your door made of?  Doors made of different materials often require different kinds of hardware.

  • If a magnet is attracted to your door, then it is a hollow metal door.  Hollow metal doors are perhaps the most popular doors to be used in commercial facilities.
  • Is your door mostly glass with a relatively slim frame around it?  Then it is probably an aluminum storefront door.
  • Wooden doors are also common and used in all of the applications as hollow metal doors.
  • FRP (Fiber Reinforced Plastic) doors are also becoming more popular all the time, and they are available in different configurations to accommodate almost every application.

Lock Prep

Commercial hollow metal or wood doors are usually prepped one of three ways:

  • Blank – no prep whatsoever
  • 86 Prep – prepared for mortise clock
  • 161 Prep – prepared for cylindrical lock, 2-3/4 inch backset, with ANSI standard 4-7/8 inch tall strike

BacksetThe 161 Prep is a prep for a cylindrical lock.  It can be identified by a 2-1/8 inch diameter hole (called the ‘bore’) centered 2-3/4 inches from the edge of the door and a an opening in the edge of the door that is 2-1/4 inches high by 1-1/8 inches wide.  Centered in this edge prep is a 1-inch diameter hole for the latch.   The distance between the edge of the door and he centerline of the door is called the “backset.”

Most Grade 1 cylindrical lever locks have through-bolts that must be drilled outside the diameter of the 2-1/8 inch hole.  Then it is said that the lockset has through-bolts “outside the prep.”

Aluminum and glass storefront doors have specialized hardware.  Most hardware designed for other kinds of doors will not fit on a narrow stile storefront door, but may fit on a wide stile door.  Aluminum doors most commonly come with a prep for an Adams Rite MS1850S deadbolt.  Adams Rite offers other locks and exit devices that fit this same prep.

Locks

Lock Functions

There are many, many lock functions, but here are a few of the most common.  Common lock functions often correspond to door use or location.  Office doors are usually equipped with office function locks:  locks that can be locked from the outside only by key, but can be locked from the inside by pushbutton or turn knob.   Classroom doors get classroom or classroom security function locks.  Single occupant bathrooms get privacy locks and/or occupancy indicator deadbolts.  Janitors’ closets and storerooms are fitted with storeroom function locks.  Non-locking doors get passage function locks:  locks that are always unlocked from both sides.

Wherever you use an electric strike you will probably also use a storeroom function lock.  You will also need a door closer.

In order to comply with ADA requirements, all locks should be equipped with lever handles.  Check with your local building inspector to make sure your choice of lever design is ADA compliant.

Keying

Even if you intend to use electronic access control, your locks will probably still have keys.   To determine which key will open which door, determine who will have access to that door.  The more doors that are opened by the same key, the greater the convenience and the greater the security risk.  Therefore key control must go hand in hand with keying.

If you are only using keys for access and have an existing master key system, it is helpful to have access to the bitting list for your system.  If you do not have it on site, perhaps the locksmith who created the system still has it.  With the bitting list a locksmith can determine whether it is possible to add more locks (more changes, s/he would say) to your system and may be able to safely add changes without creating keys that open more than one door in the system.

There are software programs on the market that create master key systems, but unless you are a locksmith I suggest you leave the keying (and the software) to a locksmith.

If you are creating a new group within an existing system – for example, you are head of maintenance at a small college that is opening a new department within an existing building – and you already have an institution-wide master key system in place, you may want to create a sub-master key that opens all the doors within this new group.  This will be convenient, but remember to keep such a key in a safe place and be careful who you give it to.  This is the essence of key control.
In addition to your new sub-master key, it is wise to key doors alike only when they will always be opened by the same people.  For example your utility closets may only be opened by your maintenance staff, so you may want to key all your utility closets alike.  They will also be accessible via the sub-master and the existing master key.

The important principle here is to realize that you put locks on door to keep people out and you give keys to people so that they can get in.  Key control is making sure the people you want to keep out don’t get the keys and the people you want to let in do.

In addition to keying software, key control software is also available.  Usually, however, if you are creating a small group of, say, 25 doors or less, a simple spreadsheet or even a hand written ledger may be all you need to keep track of your keys.

Access Control

The same principle applies to access control, but the practice of access control is much simpler.  In access control you simply give everyone their own unique credential (magnetic stripe card, proximity card, pin code, etc.).  The access control system keeps track of who accesses which door and when.   You can have one credential open all the locks, but then you have to be careful who you give that credential to.  It acts as your master key.

One advantage of access control is that you will be able to tell who accesses what door and when.  If your project will house sensitive or expensive equipment or intellectual property, you may want the ability to keep records of the movements of people who have access to it.

Another advantage of access control is that you can change who has access to a given door without changing the lock.  Often one can add and delete users from any given door right from one’s desk using the access control system software.

Other Door Hardware

Hinges

There are many, many varieties of hinges.  On small projects I have found that the hinges and doors are often reused if they are in good working condition.  But hinges must be replaced if they are damaged or worn.  Take the time to identify and learn about the hinges on your job.

The overwhelming majority of hinges in the United States are one size, finish and configuration.  They are 4-1/2 inches high and 4-1/2 inches wide; they have ball bearings to reduce friction and increase life; and, by far, most of them are satin chrome plated steel.  They are full mortise hinges because both leaves are cut in:  one is cut (or mortised) into the frame and one is cut into the door.  These are called “butt hinges,” I’m not sure why.

The correct way to measure a hinge is [height] by [width] as shown in the illustration below:

HingeMeasure

You can check out my full article on hinges here.

Door Closers

I write of door closers at length elsewhere.

For your small commercial project you need to know how you want each door closer to behave on each door.  There are some limitations.  For example, you cannot have door closers with hold-open arms on fire rated doors unless they are electric and so can be released by the fire alarm.   If you restrict your use of hold-open hardware to exterior doors you will be completely safe from code violations, but this is not always practical.   Remember, therefore, that hold open hardware on fire doors must be releasable by the fire alarm panel and you should be okay.

As mentioned earlier, the reveal dimension of your header can affect whether or not you can use a closer mounted in top jamb configuration.  Other opening idiosyncrasies – arch top doors, transoms, odd widths – can also affect your choice of door closer.  My best advice is to take good measurements and consult with your qualified hardware installer.

Auto Operators

Also called power operators or automatic door openers, auto operators are growing more in demand every year as we move toward a more inclusive society.   These devices are potentially dangerous if specified or installed incorrectly.  Therefore if you need an automatic door opener your best bet is to hire an automatic door company.   Your second best bet is to have your qualified hardware installer choose and install a low energy power operator that is designed to exert less force, thereby presenting less of a potential hazard.

Auxiliary / Decorative Hardware

On most openings one finds a door stop.   The purpose of the door stop is usually to prevent the hardware on the door from hitting and damaging the wall, but sometimes it is used to prevent the door from opening too far.   There is a great variety of door stops designed to accommodate different conditions.

In addition to door stops there may be kick plates or other protection plates, door viewers, lock guards, surface bolts, metal numerals or letters, mail slots, or various and sundry other hardware items to serve a myriad of purposes.  Most of these items are fairly self explanatory.

Kick plates, armor plates and protection plates are measured like hinges:  height x width.

Review 

Once you have assembled the information and organized it by door number, review it as best you can for accuracy and completeness.   You can always go back and check if you have to.

  • Door dimensions, handing, composition and location
  • Whether or not doors are fire rated or non-fire rated
  • List of existing hardware and/or lock preps
  • Lock functions, design, finish and keying (and access control)
  • Hinge sizes and finishes
  • Door closer functions and finishes
  • Auto operators, if any
  • Auxiliary hardware required

Armed with this information you will be on good footing when you discuss the job with your qualified door hardware installer.  Best of luck with your project.

Overview: School Security Hardware

11line

Sargent 11-Line Cylindrical (bored) Lockset

Security in our elementary and secondary schools has become much more important. Schools across the country are implementing lockdown procedures in case of emergency. Lockdowns are achieved through the use of locks, and new lock functions have been developed for use in concert with existing lock functions to answer the need for increased security.

Classroom Security Locks

A regular, traditional classroom function lock is unlocked and locked from the outside by key and the inside lever is always unlocked, allowing free egress. The problem with this function from a lockdown point of view is that, in order to lock the door, the teacher must open the door to lock it, exposing themselves and potentially their students to danger as they do so.

All major lock companies are either developing a classroom security function or assigning that application to one of their existing functions. Basically, the principal is this: in the event of an emergency the teacher can lock the outside lever handle of the classroom door from inside the classroom, thereby securing the safety of the students without endangering themselves. The inside lever remains unlocked allowing free egress. When locked, entry from the outside is by key only.

Some companies have developed classroom security function locksets in which the outside lever can be locked or unlocked with either the inside key or the outside key. This allows the teacher to continue to use the lock as a traditional classroom lock unless an actual emergency develops.

Click here for a complete description of classroom security function in a mortise lock.

 

Electric Lock Down Systems

Some school districts have opted to lock down their perimeter doors with delayed egress systems. Delayed egress systems are a way of locking exterior entrance doors from both sides while allowing for emergency egress.

Quest for the 24-Inch Exit Device with Electric Latch Retraction

Yale7100I had a lot of fun recently trying to meet a customer’s requirement for a 4-foot by 7-foot pair of doors in a hospital that needed to be fire rated and automated.   I found that Corbin and Yale (sister companies whose exit devices are almost identical) offer fire rated surface vertical rod exit devices with electric latch retraction that meet this need.   The installer will be able to put some kind of little power operator on each 24-inch leaf of this four foot pair and cram two fire rated surface vertical rod devices onto these same narrow leaves.  Doubtless it will look odd, but it will work.

Admittedly the whole idea is a bit dubious.  True, by having both leaves opened simultaneously by power operators will provide amply more than the minimum 32-inch clearance demanded by the American Disabilities act, but if anyone manually opens either leaf it certainly will not.

Sargent and Von Duprin offer 24-inch fire rated exit devices, but neither offer them with electric latch retraction.   It is unfortunately necessary to call these companies’ tech support lines in order to verify this information, since their price lists both show 24-inch possibilities without disclaiming the electric latch retraction option.  Neither the Sargent nor the Von Duprin has a note to say the 24-inch device is not available with electric latch retraction that I could see; if that is in fact the case, the buyer is left to beware the exit device order that bounces back because it was ordered with options that are mutually incompatible.

It’s good advice anyway to always call the manufacturer’s tech support whenever there is a question.  Waiting on hold is a lot better than storing thousand-dollar exit devices that didn’t work out on the job.

Note:  A reader named Rick writes in with this about Sargent electric latch retraction:  “Tom, I just stumbled across your site this evening, while doing a search for Fail Secure mag locks of all things (IR says there is one).  But I saw your latest article on latch retraction units and had to clarify the Sargent restrictions. These can be found within the catalog pages, specifically the page showing the 56 option (toward the back). It says:

         MinimumDoorWidths:
              -Wide Stile Door 28″
              – Narrow Stile Door 26″
Thank you, Rick, for this bit of info.  I should add that it is always good to check all the literature at your disposal for any information you are looking for.  Some manufacturers have more detail in their price list than in their catalog, and others vice versa.  Thanks again.